川消自動噴水滅火系統灑水噴頭如何選型
來源:http://www.xintli.net/ 日期:2023-06-20
一、濕式自動噴水滅火系統灑水噴頭的選型
1、 Selection of sprinkler heads for wet automatic sprinkler systems
1、不做吊頂的場所,當配水支管布置在梁下時,應采用直立型灑水噴頭;
1. In places without suspended ceilings, when the water distribution branch pipe is arranged under the beam, a vertical sprinkler head should be used;
2、吊頂下布置的灑水噴頭,應采用吊頂型灑水噴頭或下垂型灑水噴頭;
2. The sprinkler heads arranged under the suspended ceiling should be either ceiling type or pendant type;
3、頂板為水平面的 輕危險級、中危險Ⅰ級住宅建筑、宿舍、旅館建筑客房、醫療建筑病房和辦公室,可采用邊墻型灑水噴頭;
3. The top plate is for residential buildings, dormitories, hotel rooms, medical wards, and offices with light and medium danger levels on the horizontal plane, and can use side wall sprinkler heads;
4、易受碰撞的部位,應采用帶保護罩的灑水噴頭或吊頂型灑水噴頭;
4. For areas prone to collision, sprinkler heads with protective covers or ceiling type sprinkler heads should be used;
5、頂板為水平面,且無梁、通風管道等障礙物影響噴頭灑水的場所,可采用擴大覆蓋面積灑水噴頭;
5. In places where the top plate is a horizontal plane and there are no obstacles such as beams or ventilation ducts that affect the spraying of water by the sprinkler head, an expanded coverage area sprinkler head can be used;
6、住宅建筑和宿舍、公寓等非住宅類居住建筑宜采用家用噴頭;
6. Residential buildings and non residential residential buildings such as dormitories and apartments should use household nozzles;
7、不宜選用隱蔽式灑水噴頭,確需采用時,應僅適用于輕危險級和中危險Ⅰ級場所。
7. Concealed sprinkler heads should not be used. When necessary, they should only be used in lightly hazardous and medium hazardous Class I locations.
二、干式和預作用自動噴水滅火系統灑水噴頭的選型
2、 Selection of sprinkler heads for dry and pre action automatic sprinkler systems
干式系統、預作用系統應采用直立型灑水噴頭或干式下垂型灑水噴頭。
The dry system and pre action system should use vertical sprinkler heads or dry pendant sprinkler heads.
3、 Selection of nozzle for Sichuan Xiaoshui Water Curtain System
防火分隔水幕應采用開式灑水噴頭或水幕噴頭;
Fire separation water curtains should use open sprinkler heads or water curtain nozzles;
防護冷卻水幕應采用水幕噴頭。
The protective cooling water curtain should use a water curtain nozzle.
四、自動噴水防護冷卻系統灑水噴頭的選型
4、 Selection of Sprinkler Head for Automatic Water Spray Protection Cooling System
自動噴水防護冷卻系統可采用邊墻型灑水噴頭。
The automatic sprinkler protection cooling system can use side wall sprinkler heads.
五、下列場所宜采用快速響應灑水噴頭。當采用快速響應灑水噴頭時,系統應為濕式系統。
5、 The following locations should use quick response sprinkler heads. When using fast response sprinkler heads, the system should be a wet system.
1、公共娛樂場所、中庭環廊;
1. Public entertainment venues and atrium corridors;
2、醫院、療養院的病房及區域,老年、少兒、殘疾人的集體活動場所;
2. Wards and treatment areas in hospitals and sanatoriums, as well as collective activity venues for the elderly, children, and disabled;
3、超出消防水泵接合器供水高度的樓層;
3. Floors exceeding the water supply height of the fire pump adapter;
4、地下商業場所。
4. Underground commercial premises.
That's all for the selection of sprinkler heads for the Sichuan Fire Automatic Sprinkler System. We hope it can be of great help to you. For more information, please come to our website http://www.xintli.net Consult!